CABIN : The cabin shall be fabricated from CRCA quality steel duly welded, comprising of base frame, peripheral structure, self draining roof, entry doors and windows (as per requirement). The eight corners shall be sufficiently strengthened to facilitate transportation, lifting and placing.

Base Frame : The base frame shall be made of pressed mild steel channel section. The main structural element shall be of 100 mm x 50 mm 'C channels and cross member shall be of 'C' channels section size 75 mm x 40 mm. 5 legs at all four corners.

Side and End Walls : The side and end frame shall be made out of pressed sections of suitable profiles/pillars of sufficient strength. Exterior wall shall be made up of 18 swg (1.2MM) CRCA specially corrugated sheet whereas 9 mm MDF board will be used for interior walls. The steel sheet shall be treated for corrosion resistance. Panels shall be vertically corrugated, sheet shall be continuously welded to top side and base structure so as to offer better strength to weight ratio. All gaps will be sealed at edges and at seams, bottom etc to prevent ingress of moisture.

Flooring Systems : On the bottom frame 18 mm thick plywood, bison panel/cement Fiber board .shall be fixed by means of self taping screw. PVC vinyl flooring shall be fixed on the panel.

Roof : Self draining type roof shall be made out of 18 swg thick galvanized sheet, adequate roof bows are to be provided. Roof shall be adequately cambered for draining of rain water. Interior paneling shall be done in 9 mm MDF board with adequate insulation.

Paint : Epoxy Zinc Phosphate primer & synthetic Epoxy paint for final 2 coats. (Corrosion free and fire proof paints)

Insulation : 50 mm (2) thick glass wool insulation shall be used for walls and 75 mm thick Rock wool insulation to be provided for roof.

Inner Paneling : The interior shall be aesthetically finished so as to give custom built appearance with extremely high quality workmanship. All vertically and horizontal corners shall be neatly and smoothly finished with Aluminum sections. The paneling of side walls and roof shall be of 9 mm thick MDF (wood finish) laminated board.

Main Entry Door : The door shall be of external opening type made out of the same material as wall panels with door closing unit. The construction of the door shall be double skin steel construction with 50 mm thick Rock wool insulation. The peripheral edges of the door shall be sealed with double gaskets to make it waterproof & leak proof. The door interior shall be finished with same material matching with that of the bunk house interior. The door shall be provided with locking arrangement with separate handles of both sides of the door as required. Main door will be insulated and fitted with Godrej mortise lock and power bolt.

Aluminum Windows : Aluminum powder coated windows, sliding type shall be provided, made of aluminum section, 4 mm thick, tinted glasses are to be fitted to it.

Electrical System : The bunk house will be provided with electrical wiring suitable for 250 volt, 50 HZ single phase AC power supply. All electrical wiring shall be concealed. Suitable copper cables shall be used for lighting circuits. The copper cables used will be of 3/19 cable for lighting circuits. ISI mark and concealed in PVC conduits insulated copper wire shall be used for wiring to be done in PVC conduit with small size distribution board with MCB, protection and to separate with main supply.

Specification

1) EXTERIOR WALLS.
A) 1.2mm thick CRCA corrugated steel Sheets.
   
2) INSULATION
* (Insulation get fill in between exterior & interior walls to control heat inside the cabin.)
A) Rock wool density of 64kg/m3. B) Side wall and ceiling 50mm insulation fillings.
   
3) INTERIOR WALLS.
A) Interior walls will be made of decorative 9mm thick both side laminated (MDF) boards.
   
4) DOOR  
A) Steel door frame insulated with rock wool. B) Door closer.
C) Handles and hold draft. D) Door with locking arrangement.
   
5) WINDOW.  
A) Aluminum Double shutter sliding windows
B) Powder coated. C) 4mm tinted gray glass.
D) With safety grills. E) With monsoon shed.
   
6) WIRING.  
A) 220-240V 50HZ. B) Insulated Polycab copper wire.
C) All conceal wiring. D) Modular switch & sockets.
E) Bulkhead 1NO. F) 5Amp socket.
H) Internal C F L tube lights (With 1 year replacement warrantee)
H) Internal C F L tube lights (With 1 year replacement warrantee)
I) Main Switch board besides the main door entry.
j) Main power input socket with MCB 1NO. (Out side cabin)
   
7) AIR CONDITION.  
A) Air condition opening, with 15Amp electrical socket point. (As desired air condition can be installed)
   
8) LIFFTING HOOKS.  
A) Hooks at all corners of cabin for easy lifting and shifting.
   
9) EXTERIOR PAINTING.  
Epoxy Zinc Phosphate primer & synthetic Epoxy paint for final 2 coats. (Corrosion free and fire proof paints) shed oxferd blue & milky white.